| Assessment Year | 1994 |
|---|---|
| Principal Product | Newspaper |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $10 M to 50M |
| # of Employees | 400 |
| Plant Area |
90,000
ft2
|
| Annual Production | 13,000
ton
|
| Production Hrs. Annual | 1,800
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $228,159 | 3,702,521 |
kWh
|
$0.062 |
| Natural Gas | $58,552 | 13,055 |
MMBtu
|
$4.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,815 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,146 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $6,833 | $8,340 |
$6,833
110,199
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,313 | $58,573 |
$17,313
279,308
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,961 | $2,330 |
$1,961
31,653
kWh
|
- | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $4,332 | $7,600 |
$4,332
69,754
kWh
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $720 | $2,000 |
$720
11,723
kWh
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,881 | $1,000 | - |
$2,881
-
MMBtu
|
|
| 07 | 2.1222: Install turbulators | $775 | $1,400 | - |
$775
-
MMBtu
|
|
| TOTAL RECOMMENDED | $34,815 | $81,243 |
$31,159
502,637
kWh
|
$3,656
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $24,146 | $66,913 |
$24,146
389,507
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs