Assessment Year | 2022 |
---|---|
Principal Product | Industrial metal products |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
172,000
ft2
|
Annual Production | 19,200,000
lb
|
Production Hrs. Annual | 4,550
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,983 | 3,789,600 |
kWh
|
$0.032 |
Electricity Demand | $205,866 | 10,678 |
kW-mo/yr
|
$19.28 |
Electricity Fees | $41,363 | - |
|
- |
Natural Gas | $20,573 | 2,415 |
MMBtu
|
$8.52 |
TOTAL YEARLY COSTS | $387,785 | |||
RECOMMENDED SAVINGS* | $109,804 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $41,637 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $23,158 | - | - | - | $23,158 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,861 | $12,941 |
$2,650
82,827
kWh
|
$4,211
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,677 | - |
$4,677
146,146
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $649 | - |
$649
20,279
kWh
|
- | - | |
05 | 2.3212: Optimize plant power factor | $16,897 | $12,250 | - | - | $16,897 | |
06 | 2.9114: Use solar heat to make electricty | $50,126 | $1,220,427 |
$50,126
1,566,448
kWh
|
- | - | |
07 | 2.4151: Develop a repair/replace policy | $495 | $4,750 |
$495
15,454
kWh
|
- | - | |
08 | 2.3132: Recharge batteries on during off-peak demand periods | $6,941 | - | - |
$6,941
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $109,804 | $1,250,368 |
$58,597
1,831,154
kWh
|
$11,152
-
kW-mo/yr
|
$40,055 | ||
TOTAL IMPLEMENTED | $41,637 | $12,941 |
$7,327
228,973
kWh
|
$11,152
-
kW-mo/yr
|
$23,158 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs