| Assessment Year | 1999 |
|---|---|
| Principal Product | Corrugated Packaging |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 135 |
| Plant Area |
106,443
ft2
|
| Annual Production | 595,867,000
thousand feet
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,451 | 5,052,755 |
kWh
|
$0.024 |
| Electricity Demand | $103,485 | 10,707 |
kW-mo/yr
|
$9.67 |
| Natural Gas | $206,810 | 60,637 |
MMBtu
|
$3.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $482,224 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,579 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $931 | $400 | - | - |
$931
-
MMBtu
|
- | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $759 | $1,452 |
$469
19,930
kWh
|
$290
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 3.4155: Meter waste water | $4,407 | $2,000 | - | - | - | - | - | - |
$4,407
-
Tgal
|
|
| 04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $4,307 | $8,075 | - | - | - | - | - | $4,307 | - | |
| 05 | 3.2176: Increase use of automation | $21,820 | $100,000 | - | - | - |
$21,820
-
lb
|
- | - | - | |
| 06 | 4.611: Begin a practice of predictive / preventative maintenance | $450,000 | $79,800 | - | - | - | - | $450,000 | - | - | |
| TOTAL RECOMMENDED | $482,224 | $191,727 |
$469
19,930
kWh
|
$290
-
kW-mo/yr
|
$931
-
MMBtu
|
$21,820
-
lb
|
$450,000 | $4,307 |
$4,407
-
Tgal
|
||
| TOTAL IMPLEMENTED | $22,579 | $101,452 |
$469
19,930
kWh
|
$290
-
kW-mo/yr
|
- |
$21,820
-
lb
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs