Assessment Year 1998
Principal Product Injection Molded Plastic, Plastic Appliance Parts
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 220,000
ft2
Annual Production 5,000,000
pieces
Production Hrs. Annual 8,592
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $300,982 12,145,663
kWh
Electricity Demand $244,027 23,200
kW-mo/yr
Electricity Fees $1,722 -
Natural Gas $42,362 8,366
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $228,379 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $99,499

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Primary Product Savings
01 2.3212: Optimize plant power factor $67,516 - - $67,516
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,803 - $2,128
97,011
kWh
$1,675
-
kW-mo/yr
- -
03 3.5313: Increase amount of waste recovered for resale $28,180 - - - $28,180
-
lb
-
04 4.446: Automate finishing process $128,880 - - - - $128,880
TOTAL RECOMMENDED $228,379 - $2,128
97,011
kWh
$69,191
-
kW-mo/yr
$28,180
-
lb
$128,880
TOTAL IMPLEMENTED $99,499 - $2,128
97,011
kWh
$69,191
-
kW-mo/yr
$28,180
-
lb
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs