| Assessment Year | 1996 |
|---|---|
| Principal Product | Plastic Bottles |
| NAICS |
n/a
|
| SIC | 3085: Plastics Bottles |
| Sales Range | $10 M to 50M |
| # of Employees | 103 |
| Plant Area |
57,000
ft2
|
| Annual Production | 242,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $153,457 | 8,682,005 |
kWh
|
$0.018 |
| Electricity Demand | $145,807 | 14,462 |
kW-mo/yr
|
$10.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,761 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $617 | $2,882 |
$437
24,619
kWh
|
$180
-
kW-mo/yr
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $494 | $14,360 |
$272
15,533
kWh
|
$222
-
kW-mo/yr
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,141 | $87 |
$627
35,463
kWh
|
$514
-
kW-mo/yr
|
- | - | |
| 04 | 3.1191: Change procedures / equipment / operating conditions | $33,525 | $3,500 | - | - |
$60
-
lb
|
$33,465 | |
| 05 | 3.5311: Recover and reuse waste material | $2,984 | - | - | - |
$2,984
-
lb
|
- | |
| TOTAL RECOMMENDED | $38,761 | $20,829 |
$1,336
75,615
kWh
|
$916
-
kW-mo/yr
|
$3,044
-
lb
|
$33,465 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs