Assessment Year 1996
Principal Product Exhaust Systems and Subsystems
NAICS
n/a
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $5
M
to 10
M
# of Employees 124
Plant Area 150,000
ft2
Annual Production 17,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $138,642 4,603,458
kWh
Electricity Demand $83,842 10,021
kW-mo/yr
Electricity Fees $314 -
Natural Gas $26,676 5,357
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,756 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,078

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $3,628 $9,812 $2,242
74,150
kWh
$1,386
-
kW-mo/yr
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $190 $20 $127
4,103
kWh
$63
-
kW-mo/yr
-
03 2.7261: Install timers and/or thermostats $4,888 $200 $4,888
287,808
kWh
- -
04 3.1192: Reduce scrap production $16,000 $5,000 - - $16,000
-
lb
05 3.5311: Recover and reuse waste material $4,050 - - - $4,050
-
lb
TOTAL RECOMMENDED $28,756 $15,032 $7,257
366,061
kWh
$1,449
-
kW-mo/yr
$20,050
-
lb
TOTAL IMPLEMENTED $21,078 $5,220 $5,015
291,911
kWh
$63
-
kW-mo/yr
$16,000
-
lb
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs