Assessment Year | 1996 |
---|---|
Principal Product | Exhaust Systems and Subsystems |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $5 M to 10M |
# of Employees | 124 |
Plant Area |
150,000
ft2
|
Annual Production | 17,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $138,642 | 4,603,458 |
kWh
|
$0.030 |
Electricity Demand | $83,842 | 10,021 |
kW-mo/yr
|
$8.37 |
Electricity Fees | $314 | - |
|
- |
Natural Gas | $26,676 | 5,357 |
MMBtu
|
$4.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,756 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,078 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,628 | $9,812 |
$2,242
74,150
kWh
|
$1,386
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $190 | $20 |
$127
4,103
kWh
|
$63
-
kW-mo/yr
|
- | |
03 | 2.7261: Install timers and/or thermostats | $4,888 | $200 |
$4,888
287,808
kWh
|
- | - | |
04 | 3.1192: Reduce scrap production | $16,000 | $5,000 | - | - |
$16,000
-
lb
|
|
05 | 3.5311: Recover and reuse waste material | $4,050 | - | - | - |
$4,050
-
lb
|
|
TOTAL RECOMMENDED | $28,756 | $15,032 |
$7,257
366,061
kWh
|
$1,449
-
kW-mo/yr
|
$20,050
-
lb
|
||
TOTAL IMPLEMENTED | $21,078 | $5,220 |
$5,015
291,911
kWh
|
$63
-
kW-mo/yr
|
$16,000
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs