Assessment Year | 1995 |
---|---|
Principal Product | Portable Water Storage Tanks |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
180,000
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,784 | 2,124,560 |
kWh
|
$0.063 |
Natural Gas | $63,729 | 15,172 |
MMBtu
|
$4.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $205,653 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $977 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,714 | $1,789 |
$2,714
42,790
kWh
|
- | - | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,134 | $43 |
$1,134
17,878
kWh
|
- | - | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $848 | $1,000 | - |
$848
-
MMBtu
|
- | - | - | |
04 | 2.3212: Optimize plant power factor | $977 | $1,120 |
$977
-
kWh
|
- | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $2,406 | $3,609 |
$2,406
37,808
kWh
|
- | - | - | - | |
06 | 3.2172: Use automatic cleaning equipment | $2,033 | $1,615 | - | - |
$1,528
-
gal
|
$505
-
lb
|
- | |
07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $92,792 | $17,600 | - | - |
$89,680
-
gal
|
- |
$3,112
-
lb
|
|
08 | 3.2136: Use "wash-less" processing equipment | $99,415 | $9,240 | - | - |
$96,083
-
gal
|
- |
$3,332
-
lb
|
|
09 | 3.1192: Reduce scrap production | $3,333 | $3,124 | - | - | - | - |
$3,333
-
lb
|
|
10 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $77 | $75 | - | - | - |
$1
-
lb
|
$76
-
lb
|
|
11 | 3.8143: Recycle cleaning solvent and reuse | $(-76.0) | $89 | - | - | - | - |
$(-76.0)
-
lb
|
|
TOTAL RECOMMENDED | $205,653 | $39,304 |
$7,231
98,476
kWh
|
$848
-
MMBtu
|
$187,291
-
gal
|
$506
-
lb
|
$9,777
-
lb
|
||
TOTAL IMPLEMENTED | $977 | $1,120 |
$977
-
kWh
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs