| Assessment Year | 1995 |
|---|---|
| Principal Product | Plastic Bottle Caps |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 320 |
| Plant Area |
204,000
ft2
|
| Annual Production | 18,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,584,362 | 38,128,957 |
kWh
|
$0.042 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,153 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,704 | $1,718 |
$3,704
89,097
kWh
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $8,040 | $100 |
$8,040
193,435
kWh
|
|
| 03 | 2.3212: Optimize plant power factor | $1,409 | $3,185 |
$1,409
-
kWh
|
|
| TOTAL RECOMMENDED | $13,153 | $5,003 |
$13,153
282,532
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs