Assessment Year 2021
Principal Product Distilled spirits
NAICS 312140: Distilleries
SIC 2085: Distilled and Blended Liquors
Sales Range $100
M
to 500
M
# of Employees 100
Plant Area 1,600,000
ft2
Annual Production 20,000
Tgal
Production Hrs. Annual 7,440
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $489,668 20,218,000
kWh
Electricity Demand $797,342 48,730
kW-mo/yr
Electricity Fees $5,200 -
Natural Gas $1,203,461 450,932
MMBtu
Coal $1,035,180 231,868
MMBtu
Waste Disposal Costs
Water Usage $297,381 61,965
Tgal
Solid Waste (non-haz) $57,750 4,140,500
lb
TOTAL YEARLY COSTS $3,885,982
RECOMMENDED SAVINGS* $810,579 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Coal Savings Other Energy Savings
01 2.6212: Turn off equipment during breaks, reduce operating time $4,854 $1,665 $4,854
156,570
kWh
- - - -
02 2.4239: Eliminate or reduce compressed air usage $3,964 - $1,968
71,420
kWh
$1,996
-
kW-mo/yr
- - -
03 2.4221: Install compressor air intakes in coolest locations $685 $1,660 $332
13,838
kWh
$353
-
kW-mo/yr
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,035 $2,510 $3,378
140,739
kWh
$3,657
-
kW-mo/yr
- - -
05 2.7221: Lower temperature during the winter season and vice-versa $330 $80 $330
13,759
kWh
- - - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $267 $100 $135
4,463
kWh
$132
-
kW-mo/yr
- - -
07 2.7135: Install occupancy sensors $1,142 $640 $930
38,763
kWh
$212
-
kW-mo/yr
- - -
08 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat $731,255 $3,500,000 $143,915
10,279,625
kWh
$266,007
-
kW-mo/yr
$(-771,542.0)
-
MMBtu
$1,092,875
-
MMBtu
-
09 2.2442: Preheat combustion air with waste heat $49,643 $75,000 - - $49,643
-
MMBtu
- -
10 2.2511: Insulate bare equipment $1,250 $881 - - $1,250
-
MMBtu
- -
11 2.1321: Replace fossil fuel equipment with electrical equipment $10,154 $600 $(-379.0)
(-15,188)
kWh
- - - $10,533
-
MMBtu
TOTAL RECOMMENDED $810,579 $3,583,136 $155,463
10,703,989
kWh
$272,357
-
kW-mo/yr
$(-720,649.0)
-
MMBtu
$1,092,875
-
MMBtu
$10,533
-
MMBtu
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Coal Savings Other Energy Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs