Assessment Year | 2021 |
---|---|
Principal Product | sunroof motors |
NAICS | 335312: Motor and Generator Manufacturing |
SIC | 3621: Motors and Generators |
Sales Range | $10 M to 50M |
# of Employees | 166 |
Plant Area |
150,000
ft2
|
Annual Production | 157,000,000
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $237,234 | 4,650,000 |
kWh
|
$0.051 | |
Electricity Demand | $177,754 | 13,502 |
kW-mo/yr
|
$13.17 | |
Natural Gas | $23,675 | 2,680 |
MMBtu
|
$8.83 | |
Waste Disposal Costs | |||||
Water Usage | $1,626 | 437 |
Tgal
|
$3.72 | |
Solid Waste (non-haz) | $2,119 | 437 |
lb
|
$4.85 | |
TOTAL YEARLY COSTS | $442,408 | ||||
RECOMMENDED SAVINGS* | $19,157 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $701 | - | - | - | - | $701 | |
02 | 2.4239: Eliminate or reduce compressed air usage | $1,578 | - |
$1,388
27,220
kWh
|
$190
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,309 | $2,702 |
$3,835
75,200
kWh
|
$474
-
kW-mo/yr
|
- | - | |
04 | 2.2511: Insulate bare equipment | $1,049 | $994 |
$1,569
30,765
kWh
|
- |
$(-520.0)
-
MMBtu
|
- | |
05 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $185 | $332 |
$185
3,629
kWh
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $748 | $540 |
$443
8,685
kWh
|
$305
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $1,473 | $3,200 |
$1,473
28,872
kWh
|
- | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $1,440 | $1,484 |
$1,440
28,238
kWh
|
- | - | - | |
09 | 3.4116: Meter recycled water (to reduce sewer charges) | $1,619 | $644 | - | - | - | $1,619 | |
10 | 2.7442: Keep doors and windows shut when not on use | $1,248 | $1,000 |
$75
1,477
kWh
|
- |
$1,173
-
MMBtu
|
- | |
11 | 2.7221: Lower temperature during the winter season and vice-versa | $4,807 | $400 |
$4,807
94,248
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $19,157 | $11,296 |
$15,215
298,334
kWh
|
$969
-
kW-mo/yr
|
$653
-
MMBtu
|
$2,320 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs