ITAC Assessment: UK2105
ITAC logo
ITAC Assessment: UK2105
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product sunroof motors
NAICS 335312: Motor and Generator Manufacturing
SIC 3621: Motors and Generators
Sales Range $10
M
to 50
M
# of Employees 166
Plant Area 150,000
ft2
Annual Production 157,000,000
units
Production Hrs. Annual 6,000
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $237,234 4,650,000
kWh
Electricity Demand $177,754 13,502
kW-mo/yr
Natural Gas $23,675 2,680
MMBtu
Waste Disposal Costs
Water Usage $1,626 437
Tgal
Solid Waste (non-haz) $2,119 437
lb
TOTAL YEARLY COSTS $442,408
RECOMMENDED SAVINGS* $19,157 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.8114: Change rate schedules or other changes in utility service $701 - - - - $701
02 2.4239: Eliminate or reduce compressed air usage $1,578 - $1,388
27,220
kWh
$190
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,309 $2,702 $3,835
75,200
kWh
$474
-
kW-mo/yr
- -
04 2.2511: Insulate bare equipment $1,049 $994 $1,569
30,765
kWh
- $(-520.0)
-
MMBtu
-
05 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $185 $332 $185
3,629
kWh
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $748 $540 $443
8,685
kWh
$305
-
kW-mo/yr
- -
07 2.7135: Install occupancy sensors $1,473 $3,200 $1,473
28,872
kWh
- - -
08 2.7124: Make a practice of turning off lights when not needed $1,440 $1,484 $1,440
28,238
kWh
- - -
09 3.4116: Meter recycled water (to reduce sewer charges) $1,619 $644 - - - $1,619
10 2.7442: Keep doors and windows shut when not on use $1,248 $1,000 $75
1,477
kWh
- $1,173
-
MMBtu
-
11 2.7221: Lower temperature during the winter season and vice-versa $4,807 $400 $4,807
94,248
kWh
- - -
TOTAL RECOMMENDED $19,157 $11,296 $15,215
298,334
kWh
$969
-
kW-mo/yr
$653
-
MMBtu
$2,320
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs