| Assessment Year | 2019 |
|---|---|
| Principal Product | HVLS Fans and LED fixtures |
| NAICS | 333413: Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing |
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | less than $500 k |
| # of Employees | 500 |
| Plant Area |
300,000
ft2
|
| Annual Production | 500,000
units
|
| Production Hrs. Annual | 4,125
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $100,461 | 2,384,960 |
kWh
|
$0.042 |
| Electricity Demand | $120,952 | 6,495 |
kW-mo/yr
|
$18.62 |
| Electricity Fees | $2,405 | - |
|
- |
| Natural Gas | $30,276 | 3,383 |
MMBtu
|
$8.95 |
| TOTAL YEARLY COSTS | $254,094 | |||
| RECOMMENDED SAVINGS* | $54,816 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $483 | $1,100 |
$483
6,744
kWh
|
- | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,725 | - |
$1,508
21,566
kWh
|
$217
-
kW-mo/yr
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,355 | $2,630 |
$3,355
98,669
kWh
|
- | - | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,341 | $2,275 |
$722
21,234
kWh
|
$619
-
kW-mo/yr
|
- | - | |
| 05 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $288 | $1,045 |
$288
8,484
kWh
|
- | - | - | |
| 06 | 2.2437: Recover waste heat from equipment | $1,304 | $660 | - | - | - |
$1,304
-
MMBtu
|
|
| 07 | 2.7221: Lower temperature during the winter season and vice-versa | $2,766 | - |
$1,611
39,535
kWh
|
- | - |
$1,155
-
MMBtu
|
|
| 08 | 2.7224: Reduce space conditioning during non-working hours | $3,392 | - |
$1,531
31,854
kWh
|
- | - |
$1,861
-
MMBtu
|
|
| 09 | 2.7231: Use radiant heater for spot heating | $8,769 | $4,160 |
$585
17,200
kWh
|
$2,149
-
kW-mo/yr
|
- |
$6,035
-
MMBtu
|
|
| 10 | 2.7132: Install timers on light switches in little used areas | $107 | $223 |
$107
3,145
kWh
|
- | - | - | |
| 11 | 2.7111: Reduce illumination to minimum necessary levels | $2,742 | - |
$2,742
80,644
kWh
|
- | - | - | |
| 12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,165 | $48,242 |
$4,627
131,080
kWh
|
$9,538
-
kW-mo/yr
|
- | - | |
| 13 | 2.7134: Use photocell controls | $2,056 | - |
$2,056
18,193
kWh
|
- | - | - | |
| 14 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $36 | $36 |
$19
569
kWh
|
$17
-
kW-mo/yr
|
- | - | |
| 15 | 2.8114: Change rate schedules or other changes in utility service | $12,287 | - | - | - | $12,287 | - | |
| TOTAL RECOMMENDED | $54,816 | $60,371 |
$19,634
478,917
kWh
|
$12,540
-
kW-mo/yr
|
$12,287 |
$10,355
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs