Assessment Year 2017
Principal Product Wooden and Laminated Cabinets
NAICS 337110: Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434: Wood Kitchen Cabinets
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 310,000
ft2
Annual Production 554,400
units
Production Hrs. Annual 5,000
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $166,035 4,964,160
kWh
Electricity Demand $299,796 18,883
kW-mo/yr
Electricity Fees $5,411 -
Natural Gas $61,629 20,793
MMBtu
TOTAL YEARLY COSTS $532,871
RECOMMENDED SAVINGS* $43,567 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4152: Use only certified motor repair shops $10,415 $8,440 $4,385
132,880
kWh
$6,030
-
kW-mo/yr
-
02 2.6212: Turn off equipment during breaks, reduce operating time $9,847 $4,000 $9,847
298,400
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,878 $11,800 $1,848
56,000
kWh
$2,030
-
kW-mo/yr
-
04 2.7135: Install occupancy sensors $257 $384 $257
7,784
kWh
- -
05 2.6212: Turn off equipment during breaks, reduce operating time $3,902 $10,000 $2,387
72,330
kWh
$1,515
-
kW-mo/yr
-
06 2.7293: Install dry sprinkler system or other method to reduce heating requirements $1,690 $2,875 $1,039
31,481
kWh
$651
-
kW-mo/yr
-
07 2.1114: Limit and control secondary combustion air in furnace $3,158 $393 - - $3,158
-
MMBtu
08 2.1233: Analyze flue gas for proper air/fuel ratio $1,875 $1,500 - - $1,875
-
MMBtu
09 2.4239: Eliminate or reduce compressed air usage $2,426 $1,350 $2,426
74,608
kWh
- -
10 2.4231: Reduce the pressure of compressed air to the minimum required $1,915 - $1,688
51,173
kWh
$227
-
kW-mo/yr
-
11 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,452 $2,100 $1,452
44,000
kWh
- -
12 2.7142: Utilize higher efficiency lamps and/or ballasts $1,682 $5,300 $840
23,350
kWh
$842
-
kW-mo/yr
-
13 2.7134: Use photocell controls $1,070 $800 $1,070
29,744
kWh
- -
TOTAL RECOMMENDED $43,567 $48,942 $27,239
821,750
kWh
$11,295
-
kW-mo/yr
$5,033
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs