Assessment Year | 2016 |
---|---|
Principal Product | Shampoos and Conditioners |
NAICS | 325620: Toilet Preparation Manufacturing |
SIC | 2844: Perfumes, Cosmetics, and Other Toilet Preparations |
Sales Range | $100 M to 500M |
# of Employees | 341 |
Plant Area |
304,000
ft2
|
Annual Production | 183,000,000
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $503,809 | 11,144,781 |
kWh
|
$0.045 | |
Electricity Demand | $300,211 | 22,472 |
kW-mo/yr
|
$13.36 | |
Electricity Fees | $1,748 | - |
|
- | |
Natural Gas | $292,361 | 44,492 |
MMBtu
|
$6.57 | |
Waste Disposal Costs | |||||
Water Usage | $186,361 | 35,980,174 |
Tgal
|
$0.005 | |
TOTAL YEARLY COSTS | $1,284,490 | ||||
RECOMMENDED SAVINGS* | $210,664 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $171,036 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $89,730 | $85,358 |
$55,841
1,235,238
kWh
|
$24,729
-
kW-mo/yr
|
- | $9,160 | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,306 | $1,445 |
$3,306
73,140
kWh
|
- | - | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $18,272 | $35,000 |
$6,729
148,870
kWh
|
$11,543
-
kW-mo/yr
|
- | - | |
04 | 2.4322: Use or replace with energy efficient substitutes | $9,160 | $14,700 |
$1,785
39,500
kWh
|
$7,375
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,058 | - |
$3,058
67,663
kWh
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,304 | $1,600 |
$1,304
28,859
kWh
|
- | - | - | |
07 | 2.7224: Reduce space conditioning during non-working hours | $16,948 | - |
$8,182
181,008
kWh
|
$2,886
-
kW-mo/yr
|
$5,880
-
MMBtu
|
- | |
08 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $33,264 | $30,000 | - | - |
$33,264
-
MMBtu
|
- | |
09 | 2.2442: Preheat combustion air with waste heat | $33,165 | $58,682 | - | - |
$33,165
-
MMBtu
|
- | |
10 | 2.1113: Reduce combustion air flow to optimum | $2,457 | - | - | - |
$2,457
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $210,664 | $226,785 |
$80,205
1,774,278
kWh
|
$46,533
-
kW-mo/yr
|
$74,766
-
MMBtu
|
$9,160 | ||
TOTAL IMPLEMENTED | $171,036 | $195,340 |
$73,841
1,633,475
kWh
|
$46,533
-
kW-mo/yr
|
$41,502
-
MMBtu
|
$9,160 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs