Assessment Year | 2014 |
---|---|
Principal Product | Dairy Producs |
NAICS | 311513: Cheese Manufacturing |
SIC | 2022: Natural, Processed, and Imitation Cheese |
Sales Range | $100 M to 500M |
# of Employees | 400 |
Plant Area |
117,800
ft2
|
Annual Production | 14,464
ton
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $409,732 | 11,361,947 |
kWh
|
$0.036 |
Electricity Demand | $357,313 | 27,505 |
kW-mo/yr
|
$12.99 |
Electricity Fees | $160,316 | - |
|
- |
Natural Gas | $585,132 | 63,420 |
MMBtu
|
$9.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $598,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $132,027 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.3133: Use other waste concentration methods | $200,000 | - | - | - | - | - | $200,000 | - | |
02 | 2.3192: Use fossil fuel powered generator during peak demand periods | $194,446 | $20,000 | - | - | - | - | - | $194,446 | |
03 | 2.8114: Change rate schedules or other changes in utility service | $33,427 | - | - | - | - | - | $33,427 | - | |
04 | 2.2442: Preheat combustion air with waste heat | $32,296 | $39,600 | - | - | - |
$32,296
-
MMBtu
|
- | - | |
05 | 2.8114: Change rate schedules or other changes in utility service | $28,307 | - | - | - | - | - | $28,307 | - | |
06 | 2.2135: Repair and eliminate steam leaks | $27,426 | $2,678 | - | - | - |
$27,426
-
MMBtu
|
- | - | |
07 | 2.3212: Optimize plant power factor | $20,457 | $15,610 | - | - | $20,457 | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,745 | $46,464 |
$12,055
334,847
kWh
|
$7,690
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.2437: Recover waste heat from equipment | $15,146 | $1,540 | - | - | - |
$15,146
-
MMBtu
|
- | - | |
10 | 2.1233: Analyze flue gas for proper air/fuel ratio | $13,374 | $24,100 | - | - | - |
$13,374
-
MMBtu
|
- | - | |
11 | 2.4224: Upgrade controls on compressors | $8,300 | $25,000 |
$8,300
230,000
kWh
|
- | - | - | - | - | |
12 | 2.2123: Insulate feedwater tank | $3,480 | $1,769 | - | - | - |
$3,480
-
MMBtu
|
- | - | |
13 | 2.4221: Install compressor air intakes in coolest locations | $2,369 | - |
$2,369
65,798
kWh
|
- | - | - | - | - | |
14 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $103 | $30 |
$103
2,865
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $598,876 | $176,791 |
$22,827
633,510
kWh
|
$7,690
-
kW-mo/yr
|
$20,457 |
$91,722
-
MMBtu
|
$261,734 | $194,446 | ||
TOTAL IMPLEMENTED | $132,027 | $131,791 |
$12,158
337,712
kWh
|
$7,690
-
kW-mo/yr
|
$20,457 |
$91,722
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs