ITAC Assessment: UK1402
ITAC logo
ITAC Assessment: UK1402
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2014
Principal Product Aerial Devices
NAICS 333120: Construction Machinery Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $5
M
to 10
M
# of Employees 550
Plant Area 200,000
ft2
Annual Production 100
pieces
Production Hrs. Annual 5,000
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $309,016 8,408,700
kWh
Electricity Demand $181,699 23,049
kW-mo/yr
Electricity Fees $71,050 -
Natural Gas $129,572 24,452
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $58,828 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4221: Install compressor air intakes in coolest locations $3,710 $4,500 - - $3,710
-
MMBtu
02 2.4221: Install compressor air intakes in coolest locations $1,696 $1,000 $1,119
30,500
kWh
$577
-
kW-mo/yr
-
03 2.6127: Maintain air filters by cleaning or replacement $2,530 $1,500 $776
21,131
kWh
- $1,754
-
MMBtu
04 2.7224: Reduce space conditioning during non-working hours $1,833 - $534
14,556
kWh
- $1,299
-
MMBtu
05 2.1121: Use insulation in furnaces to facilitate heating / cooling $34,700 $40,000 - - $34,700
-
MMBtu
06 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $1,409 - $1,409
38,400
kWh
- -
07 2.7134: Use photocell controls $1,297 $1,125 $824
22,265
kWh
$473
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $11,101 $3,241 $11,101
317,180
kWh
- -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $552 $524 $552
15,047
kWh
- -
TOTAL RECOMMENDED $58,828 $51,890 $16,315
459,079
kWh
$1,050
-
kW-mo/yr
$41,463
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs