Assessment Year | 2010 |
---|---|
Principal Product | Fiberglass Reinforced Panels |
NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
68,000
ft2
|
Annual Production | 15,080
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,825 | 2,348,452 |
kWh
|
$0.033 |
Electricity Demand | $107,472 | 620 |
kW-mo/yr
|
$173.34 |
Natural Gas | $3,515 | 8,968 |
MMBtu
|
$0.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $111,071 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,592 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $27,511 | $30,000 |
$(-3,500.0)
(-87,500)
kWh
|
$37,261
-
kW-mo/yr
|
- | $(-6,250.0) | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $644 | $1 |
$342
8,550
kWh
|
$302
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,408 | $5,940 |
$2,392
59,798
kWh
|
$4,016
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,757 | $4,868 |
$1,457
36,426
kWh
|
$2,447
-
kW-mo/yr
|
- | - | $(-147.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,925 | $4,465 |
$988
24,695
kWh
|
$1,014
-
kW-mo/yr
|
- | - | $(-77.0) | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,316 | $2,585 |
$701
17,524
kWh
|
$631
-
kW-mo/yr
|
- | - | $(-16.0) | |
07 | 2.7135: Install occupancy sensors | $50 | $45 |
$50
1,238
kWh
|
- | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $535 | $500 |
$433
10,830
kWh
|
$727
-
kW-mo/yr
|
- | $(-625.0) | - | |
09 | 2.4322: Use or replace with energy efficient substitutes | $513 | $1,580 |
$170
4,250
kWh
|
$343
-
kW-mo/yr
|
- | - | - | |
10 | 2.1116: Improve combustion control capability | $17,532 | $7,000 |
$3,305
82,630
kWh
|
- |
$14,227
-
MMBtu
|
- | - | |
11 | 2.2511: Insulate bare equipment | $3,075 | $8,700 |
$1,020
25,500
kWh
|
$2,055
-
kW-mo/yr
|
- | - | - | |
12 | 2.2437: Recover waste heat from equipment | $34,849 | $39,289 |
$2,345
58,637
kWh
|
- |
$32,504
-
MMBtu
|
- | - | |
13 | 2.2533: Replace air curtain doors with solid doors | $7,994 | $45,000 |
$3,494
87,359
kWh
|
- | - | - | $4,500 | |
14 | 2.7231: Use radiant heater for spot heating | $4,962 | $4,550 |
$9,504
237,600
kWh
|
$8,400
-
kW-mo/yr
|
$(-12,942.0)
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $111,071 | $154,523 |
$22,701
567,537
kWh
|
$57,196
-
kW-mo/yr
|
$33,789
-
MMBtu
|
$(-6,875.0) | $4,260 | ||
TOTAL IMPLEMENTED | $37,592 | $31,489 |
$19,292
482,303
kWh
|
$17,880
-
kW-mo/yr
|
$1,285
-
MMBtu
|
$(-625.0) | $(-240.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs