Assessment Year | 2012 |
---|---|
Principal Product | engines |
NAICS | 333618: Other Engine Equipment Manufacturing |
SIC | 3519: Internal Combustion Engines, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 97 |
Plant Area |
92,000
ft2
|
Annual Production | 7,000
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,628 | 1,580,431 |
kWh
|
$0.035 |
Electricity Demand | $95,999 | 8,739 |
kW-mo/yr
|
$10.99 |
Electricity Fees | $37,352 | - |
|
- |
Natural Gas | $18,357 | 2,236 |
MMBtu
|
$8.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,551 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.4114: Replace city water with recycled water via cooling tower | $57,123 | $150,767 | - | - | - |
$57,123
-
Tgal
|
|
02 | 2.4224: Upgrade controls on compressors | $10,251 | $11,250 |
$4,454
127,255
kWh
|
$5,797
-
kW-mo/yr
|
- | - | |
03 | 2.3212: Optimize plant power factor | $6,631 | $11,880 | - | - | $6,631 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $546 | $500 |
$546
15,600
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $74,551 | $174,397 |
$5,000
142,855
kWh
|
$5,797
-
kW-mo/yr
|
$6,631 |
$57,123
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs