| Assessment Year | 2026 |
|---|---|
| Principal Product | Fiber-Based Tableware |
| NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
| SIC | 3497: Metal Foil and Leaf |
| Sales Range | $10 M to 50M |
| # of Employees | 149 |
| Plant Area |
550,000
ft2
|
| Annual Production | 9,490
ton
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,890,121 | 45,436,320 |
kWh
|
$0.064 | |
| Electricity Fees | $281,375 | - |
|
- | |
| Natural Gas | $169,197 | 21,000 |
MMBtu
|
$8.06 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,200,000 | 131,000 |
Tgal
|
$9.16 | |
| Water Disposal | $238,000 | 30,000 |
Tgal
|
$7.93 | |
| TOTAL YEARLY COSTS | $4,778,693 | ||||
| RECOMMENDED SAVINGS* | $743,299 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $347,581 | $1,529,500 |
$537,600
8,400,000
kWh
|
$(-106,019.0)
-
MMBtu
|
$(-84,000.0) | |
| 02 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $203,555 | $244,447 |
$203,555
3,180,542
kWh
|
- | - | |
| 03 | 2.6231: Utilize controls to operate equipment only when needed | $58,159 | $7,500 |
$58,159
908,726
kWh
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $23,113 | - |
$23,113
361,140
kWh
|
- | - | |
| 05 | 2.4237: Substitute compressed air cooling with water or air cooling | $12,689 | $2,700 |
$12,689
198,273
kWh
|
- | - | |
| 06 | 2.2623: Minimize condenser cooling water temperature | $11,638 | $28,395 |
$11,638
181,838
kWh
|
- | - | |
| 07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,076 | - | - |
$5,076
-
MMBtu
|
- | |
| 08 | 4.424: Improve space comfort conditioning | $56,488 | $22,740 |
$(-1,752.0)
(-27,382)
kWh
|
- | $58,240 | |
| 09 | 4.652: Replace existing equipment with more suitable substitutes | $25,000 | $3,560 | - | - | $25,000 | |
| TOTAL RECOMMENDED | $743,299 | $1,838,842 |
$845,002
13,203,137
kWh
|
$(-100,943.0)
-
MMBtu
|
$(-760.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs