| Assessment Year | 2026 |
|---|---|
| Principal Product | Fiberglass Insulation |
| NAICS | 327993: Mineral Wool Manufacturing |
| SIC | 3296: Mineral Wool |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
700,000
ft2
|
| Annual Production | 71,947,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,348,423 | 56,083,200 |
kWh
|
$0.042 | |
| Electricity Demand | $1,083,166 | 91,910 |
kW-mo/yr
|
$11.79 | |
| Electricity Fees | $472,015 | - |
|
- | |
| Natural Gas | $168,051 | 123,990 |
MMBtu
|
$1.36 | |
| Waste Disposal Costs | |||||
| Water Usage | $149,183 | 37,774 |
Tgal
|
$3.95 | |
| TOTAL YEARLY COSTS | $4,220,838 | ||||
| RECOMMENDED SAVINGS* | $846,160 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $343,863 | $301,728 |
$235,549
5,608,320
kWh
|
$108,314
-
kW-mo/yr
|
- | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $149,445 | $229,832 |
$149,445
3,558,213
kWh
|
- | - | - | |
| 03 | 2.9114: Use solar heat to make electricty | $136,120 | $806,520 |
$65,410
1,557,370
kWh
|
$70,710
-
kW-mo/yr
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $53,750 | - |
$53,750
1,279,763
kWh
|
- | - | - | |
| 05 | 2.6125: Keep equipment clean | $3,800 | $1,300 |
$3,800
90,484
kWh
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,417 | $356 |
$2,417
57,554
kWh
|
- | - | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,042 | - |
$1,615
38,458
kWh
|
- | $221 | $206 | |
| 08 | 4.113: Install refrigeration system to cool product | $127,680 | $12,000 |
$(-16,114.0)
(-384,389)
kWh
|
$(-6,206.0)
-
kW-mo/yr
|
- | $150,000 | |
| 09 | 4.424: Improve space comfort conditioning | $27,043 | $4,272 |
$(-604.0)
(-14,387)
kWh
|
$(-745.0)
-
kW-mo/yr
|
- | $28,392 | |
| TOTAL RECOMMENDED | $846,160 | $1,356,008 |
$495,268
11,791,386
kWh
|
$172,073
-
kW-mo/yr
|
$221 | $178,598 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs