Assessment Year | 2012 |
---|---|
Principal Product | Fiber optisc components |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 242 |
Plant Area |
64,500
ft2
|
Annual Production | 90,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $395,873 | 4,072,400 |
kWh
|
$0.097 |
Electricity Demand | $70,304 | 8,248 |
kW-mo/yr
|
$8.52 |
LPG | $51,177 | 2,366 |
MMBtu
|
$21.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,706 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,138 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $3,246 | $1,750 |
$3,246
33,467
kWh
|
|
02 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $1,986 | $7,500 |
$1,986
20,478
kWh
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,892 | $4,075 |
$1,892
19,505
kWh
|
|
04 | 2.2611: Moderate cooling tower outlet temperature | $1,582 | $4,075 |
$1,582
16,307
kWh
|
|
TOTAL RECOMMENDED | $8,706 | $17,400 |
$8,706
89,757
kWh
|
||
TOTAL IMPLEMENTED | $5,138 | $5,825 |
$5,138
52,972
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs