ITAC Assessment: MA0690
ITAC logo
ITAC Assessment: MA0690
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2012
Principal Product Fiber optisc components
NAICS 327215: Glass Product Manufacturing Made of Purchased Glass
SIC 3231: Glass Products, Made of Purchased Glass
Sales Range $10
M
to 50
M
# of Employees 242
Plant Area 64,500
ft2
Annual Production 90,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $395,873 4,072,400
kWh
Electricity Demand $70,304 8,248
kW-mo/yr
LPG $51,177 2,366
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,706 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,138

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.2511: Insulate bare equipment $3,246 $1,750 $3,246
33,467
kWh
02 2.2614: Use cooling tower or economizer to replace chiller cooling $1,986 $7,500 $1,986
20,478
kWh
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,892 $4,075 $1,892
19,505
kWh
04 2.2611: Moderate cooling tower outlet temperature $1,582 $4,075 $1,582
16,307
kWh
TOTAL RECOMMENDED $8,706 $17,400 $8,706
89,757
kWh
TOTAL IMPLEMENTED $5,138 $5,825 $5,138
52,972
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs