Assessment Year | 2015 |
---|---|
Principal Product | Aerosol Manufacturing |
NAICS | 332431: Metal Can Manufacturing |
SIC | 3411: Metal Cans |
Sales Range | $50 M to 100M |
# of Employees | 75 |
Plant Area |
142,000
ft2
|
Annual Production | 200,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,408 | 3,602,100 |
kWh
|
$0.040 |
Electricity Demand | $90,142 | 15,708 |
kW-mo/yr
|
$5.74 |
Natural Gas | $44,500 | 5,172 |
MMBtu
|
$8.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,581 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,747 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $39,935 | $152,353 |
$30,726
772,022
kWh
|
$9,209
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $7,960 | $15,939 |
$7,960
199,995
kWh
|
- | - | |
03 | 2.1133: Adjust burners for efficient operation | $6,030 | $12,000 | - | - |
$6,030
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,651 | $225 |
$2,834
71,201
kWh
|
$817
-
kW-mo/yr
|
- | |
05 | 2.4239: Eliminate or reduce compressed air usage | $2,708 | $500 |
$2,708
68,040
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,247 | $3,000 |
$2,247
56,457
kWh
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,849 | $125 |
$1,435
36,061
kWh
|
$414
-
kW-mo/yr
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,201 | $1,750 |
$1,028
25,818
kWh
|
$173
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $65,581 | $185,892 |
$48,938
1,229,594
kWh
|
$10,613
-
kW-mo/yr
|
$6,030
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,747 | $3,350 |
$6,516
163,719
kWh
|
$1,231
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs