Assessment Year | 2024 |
---|---|
Principal Product | PVC Conduit and Fittings |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $50 M to 100M |
# of Employees | 65 |
Plant Area |
27,600
ft2
|
Annual Production | 50,392,100
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $554,742 | 9,828,939 |
kWh
|
$0.056 |
Electricity Demand | $69,194 | 16,274 |
kW-mo/yr
|
$4.25 |
Electricity Fees | $28,753 | - |
|
- |
LPG | $13,023 | 979 |
MMBtu
|
$13.30 |
TOTAL YEARLY COSTS | $665,712 | |||
RECOMMENDED SAVINGS* | $231,789 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $41,219 | $322,608 |
$37,137
663,164
kWh
|
$4,082
-
kW-mo/yr
|
- | |
02 | 2.3191: Use demand controller or load shedder | $43,371 | $52,879 |
$38,529
688,026
kWh
|
$4,842
-
kW-mo/yr
|
- | |
03 | 2.2511: Insulate bare equipment | $13,853 | $3,888 |
$13,853
247,376
kWh
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $10,345 | $12,420 |
$9,155
163,477
kWh
|
$1,190
-
kW-mo/yr
|
- | |
05 | 2.4321: Upgrade obsolete equipment | $10,345 | $46,500 |
$8,750
156,250
kWh
|
$1,595
-
kW-mo/yr
|
- | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $5,789 | $25,360 |
$5,789
103,373
kWh
|
- | - | |
07 | 2.2623: Minimize condenser cooling water temperature | $5,875 | $6,148 |
$5,875
104,906
kWh
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,035 | - |
$5,035
88,222
kWh
|
- | - | |
09 | 4.661: Level zero – install control systems for existing equipment | $16,512 | $11,225 |
$16,512
294,868
kWh
|
- | - | |
10 | 4.662: Level one – add communication using iiot devices to existing control system to modify operations | $46,005 | - |
$46,005
821,512
kWh
|
- | - | |
11 | 4.424: Improve space comfort conditioning | $30,240 | $788 | - | - | $30,240 | |
12 | 4.463: Modify facility to avoid excess maintenance costs | $3,200 | $3,200 | - | - | $3,200 | |
TOTAL RECOMMENDED | $231,789 | $485,016 |
$186,640
3,331,174
kWh
|
$11,709
-
kW-mo/yr
|
$33,440 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs