Assessment Year | 2021 |
---|---|
Principal Product | Newspapers and Other Publications |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
65,119
ft2
|
Annual Production | 9,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $390,809 | 3,686,880 |
kWh
|
$0.11 |
Electricity Demand | $64,929 | 7,429 |
kW-mo/yr
|
$8.74 |
Electricity Fees | $15,104 | - |
|
- |
TOTAL YEARLY COSTS | $470,842 | |||
RECOMMENDED SAVINGS* | $104,934 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $54,494 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,828 | $23,023 |
$24,828
234,225
kWh
|
- | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $18,925 | $25,340 |
$18,925
178,538
kWh
|
- | |
03 | 2.4112: Install soft-start to eliminate nuisance trips | $16,113 | $14,830 |
$16,113
152,014
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $12,766 | $5,229 |
$11,399
107,540
kWh
|
$1,367
-
kW-mo/yr
|
|
05 | 2.7212: Install or upgrade insulation on hvac distribution systems | $11,660 | $40,000 |
$11,660
110,000
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,252 | $1,985 |
$5,618
52,998
kWh
|
$634
-
kW-mo/yr
|
|
07 | 2.2211: Use optimum temperature | $3,887 | - |
$3,887
36,667
kWh
|
- | |
08 | 2.2623: Minimize condenser cooling water temperature | $3,742 | $3,746 |
$3,742
35,300
kWh
|
- | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,071 | $495 |
$3,071
28,971
kWh
|
- | |
10 | 2.4239: Eliminate or reduce compressed air usage | $1,868 | - |
$1,868
17,619
kWh
|
- | |
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,822 | - |
$1,822
15,824
kWh
|
- | |
TOTAL RECOMMENDED | $104,934 | $114,648 |
$102,933
969,696
kWh
|
$2,001
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $54,494 | $30,732 |
$52,493
493,844
kWh
|
$2,001
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs