Assessment Year | 2019 |
---|---|
Principal Product | Rutile, Leucoxene, Ilmenite, Staurolite, Zircon and Kyanite |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
100,000
ft2
|
Annual Production | 95,977
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $93,874 | 2,528,400 |
kWh
|
$0.037 |
Electricity Demand | $57,840 | 13,043 |
kW-mo/yr
|
$4.43 |
Electricity Fees | $8,226 | - |
|
- |
Natural Gas | $797,516 | 233,264 |
MMBtu
|
$3.42 |
TOTAL YEARLY COSTS | $957,456 | |||
RECOMMENDED SAVINGS* | $96,439 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $93,942 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $40,174 | $25,000 | - | - |
$40,174
-
MMBtu
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $23,919 | $1,400 | - | - |
$23,919
-
MMBtu
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $9,352 | $25,847 |
$5,847
158,040
kWh
|
$3,505
-
kW-mo/yr
|
- | - | |
04 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $1,403 | $5,998 |
$1,403
37,913
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,301 | $421 |
$1,301
35,168
kWh
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $1,094 | $230 |
$1,094
29,569
kWh
|
- | - | - | |
07 | 3.7214: Reduce or eliminate waste | $19,196 | $40,500 | - | - | - | $19,196 | |
TOTAL RECOMMENDED | $96,439 | $99,396 |
$9,645
260,690
kWh
|
$3,505
-
kW-mo/yr
|
$64,093
-
MMBtu
|
$19,196 | ||
TOTAL IMPLEMENTED | $93,942 | $93,168 |
$7,148
193,208
kWh
|
$3,505
-
kW-mo/yr
|
$64,093
-
MMBtu
|
$19,196 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs