Assessment Year | 1986 |
---|---|
Principal Product | GEARS & GEAR BOXES |
NAICS |
n/a
|
SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $268,805 | 4,267,292 |
kWh
|
$0.063 |
Natural Gas | $52,504 | 9,981 |
MMBtu
|
$5.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,528 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $16,780 | - |
$19,440
-
kWh
|
- | $(-2,660.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,528 | $2,300 |
$9,471
252,345
kWh
|
$(-2,323.0)
-
MMBtu
|
$380 | |
03 | 2.7421: Reduce glazed areas in buildings | $3,892 | $3,510 | - |
$3,892
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $28,200 | $5,810 |
$28,911
252,345
kWh
|
$1,569
-
MMBtu
|
$(-2,280.0) | ||
TOTAL IMPLEMENTED | $7,528 | $2,300 |
$9,471
252,345
kWh
|
$(-2,323.0)
-
MMBtu
|
$380 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs