ITAC Assessment: UD0196
ITAC logo
ITAC Assessment: UD0196
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1986
Principal Product GEARS & GEAR BOXES
NAICS
n/a
SIC 3566: Speed Changers, Industrial High-Speed Drives, and Gears
Sales Range $10
M
to 50
M
# of Employees 220
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 6,000
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $268,805 4,267,292
kWh
Natural Gas $52,504 9,981
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,200 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,528

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $16,780 - $19,440
-
kWh
- $(-2,660.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,528 $2,300 $9,471
252,345
kWh
$(-2,323.0)
-
MMBtu
$380
03 2.7421: Reduce glazed areas in buildings $3,892 $3,510 - $3,892
-
MMBtu
-
TOTAL RECOMMENDED $28,200 $5,810 $28,911
252,345
kWh
$1,569
-
MMBtu
$(-2,280.0)
TOTAL IMPLEMENTED $7,528 $2,300 $9,471
252,345
kWh
$(-2,323.0)
-
MMBtu
$380
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs