Assessment Year | 2019 |
---|---|
Principal Product | Corn and Potatoes Snacks |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
250,000
ft2
|
Annual Production | 50,000
ton
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,213,979 | 19,267,006 |
kWh
|
$0.063 | |
Electricity Demand | $265,213 | 31,566 |
kW-mo/yr
|
$8.40 | |
Electricity Fees | $149,418 | - |
|
- | |
Natural Gas | $141,076 | 320,097 |
MMBtu
|
$0.44 | |
Waste Disposal Costs | |||||
Water Usage | $299,183 | 114,003 |
Tgal
|
$2.62 | |
Water Disposal | $805,779 | 110,202 |
Tgal
|
$7.31 | |
TOTAL YEARLY COSTS | $2,874,648 | ||||
RECOMMENDED SAVINGS* | $258,333 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $234,011 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2622: Replace existing chiller with high efficiency model | $109,260 | $320,000 |
$97,161
1,542,240
kWh
|
$12,099
-
kW-mo/yr
|
- | - | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $67,747 | $55,000 |
$60,691
963,350
kWh
|
- |
$7,056
-
MMBtu
|
- | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $29,180 | $25,340 |
$29,180
463,178
kWh
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $12,645 | $10,000 | - | - |
$12,645
-
MMBtu
|
- | |
05 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $11,158 | $9,464 |
$11,158
177,113
kWh
|
- | - | - | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $2,139 | $10,000 | - | - |
$2,139
-
MMBtu
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,882 | $2,800 | - | - |
$1,882
-
MMBtu
|
- | |
08 | 3.7214: Reduce or eliminate waste | $24,322 | $15,000 |
$(-607.0)
(-9,634)
kWh
|
- |
$(-71.0)
-
MMBtu
|
$25,000 | |
TOTAL RECOMMENDED | $258,333 | $447,604 |
$197,583
3,136,247
kWh
|
$12,099
-
kW-mo/yr
|
$23,651
-
MMBtu
|
$25,000 | ||
TOTAL IMPLEMENTED | $234,011 | $432,604 |
$198,190
3,145,881
kWh
|
$12,099
-
kW-mo/yr
|
$23,722
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs