ITAC Assessment: UF0523
ITAC logo
ITAC Assessment: UF0523
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2019
Principal Product Roofing Insulation and Composite Materials
NAICS 324122: Asphalt Shingle and Coating Materials Manufacturing
SIC 2952: Asphalt Felts and Coatings
Sales Range $50
M
to 100
M
# of Employees 132
Plant Area 400,000
ft2
Annual Production 8,300,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $529,340 9,298,571
kWh
Electricity Demand $112,366 16,722
kW-mo/yr
Electricity Fees $78,520 -
Natural Gas $817,470 373,302
MMBtu
Waste Disposal Costs
Water Usage $26,036 10,474
Tgal
Water Disposal $27,786 3,711
Tgal
TOTAL YEARLY COSTS $1,591,518
RECOMMENDED SAVINGS* $108,567 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,449

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.8212: Reduce delivery schedules $43,506 - - - - $40,000 $3,506 -
02 2.1233: Analyze flue gas for proper air/fuel ratio $19,621 $2,800 - - $19,621
-
MMBtu
- - -
03 2.2414: Use waste heat from hot flue gases to preheat $14,666 $30,000 - - $14,666
-
MMBtu
- - -
04 2.2135: Repair and eliminate steam leaks $14,533 $1,600 - - $14,533
-
MMBtu
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $7,991 $4,959 $6,879
120,888
kWh
$1,112
-
kW-mo/yr
- - - -
06 2.2136: Install / repair insulation on steam lines $2,925 $1,308 - - $2,925
-
MMBtu
- - -
07 2.4222: Install adequate dryers on air lines to eliminate blowdown $2,600 $9,464 $2,600
45,693
kWh
- - - - -
08 2.6218: Turn off equipment when not in use $1,990 - $1,990
34,969
kWh
- - - - -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $735 - $537
9,442
kWh
- - $90 - $108
TOTAL RECOMMENDED $108,567 $50,131 $12,006
210,992
kWh
$1,112
-
kW-mo/yr
$51,745
-
MMBtu
$40,090 $3,506 $108
TOTAL IMPLEMENTED $25,449 $7,867 $6,879
120,888
kWh
$1,112
-
kW-mo/yr
$17,458
-
MMBtu
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs