Assessment Year | 2009 |
---|---|
Principal Product | electronics |
NAICS | 334419: Other Electronic Component Manufacturing |
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
150,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 4,590
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $395,986 | 6,016,186 |
kWh
|
$0.066 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $97,185 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,322 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 3.7135: Minimize use of rags through worker training | $1,734 | - |
$1,734
26,276
kWh
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,365 | - |
$1,365
20,689
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,980 | $5,895 |
$11,980
130,650
kWh
|
|
04 | 2.7243: Improve air circulation with destratification fans / other methods | $6,371 | $2,260 |
$6,371
70,019
kWh
|
|
05 | 2.7135: Install occupancy sensors | $872 | $1,971 |
$872
13,217
kWh
|
|
06 | 2.4225: Install common header on compressors | $674 | - |
$674
7,412
kWh
|
|
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,285 | - |
$4,285
47,096
kWh
|
|
08 | 2.3212: Optimize plant power factor | $44,818 | $3,326 |
$44,818
-
kWh
|
|
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $25,086 | - |
$25,086
275,678
kWh
|
|
TOTAL RECOMMENDED | $97,185 | $13,452 |
$97,185
591,037
kWh
|
||
TOTAL IMPLEMENTED | $45,322 | $7,866 |
$45,322
513,606
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs