Assessment Year 2009
Principal Product electronics
NAICS 334419: Other Electronic Component Manufacturing
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 150,000
ft2
Annual Production 500,000
pieces
Production Hrs. Annual 4,590
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $395,986 6,016,186
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $97,185 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,322

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 3.7135: Minimize use of rags through worker training $1,734 - $1,734
26,276
kWh
02 2.6212: Turn off equipment during breaks, reduce operating time $1,365 - $1,365
20,689
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $11,980 $5,895 $11,980
130,650
kWh
04 2.7243: Improve air circulation with destratification fans / other methods $6,371 $2,260 $6,371
70,019
kWh
05 2.7135: Install occupancy sensors $872 $1,971 $872
13,217
kWh
06 2.4225: Install common header on compressors $674 - $674
7,412
kWh
07 2.6212: Turn off equipment during breaks, reduce operating time $4,285 - $4,285
47,096
kWh
08 2.3212: Optimize plant power factor $44,818 $3,326 $44,818
-
kWh
09 2.6212: Turn off equipment during breaks, reduce operating time $25,086 - $25,086
275,678
kWh
TOTAL RECOMMENDED $97,185 $13,452 $97,185
591,037
kWh
TOTAL IMPLEMENTED $45,322 $7,866 $45,322
513,606
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs