Assessment Year | 2009 |
---|---|
Principal Product | Skidded Equipment, Precision Cleaning |
NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
293,159
ft2
|
Annual Production | 7,000,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,888 | 788,562 |
kWh
|
$0.085 |
Electricity Demand | $23,220 | 3,015 |
kW-mo/yr
|
$7.70 |
Electricity Fees | $8,225 | - |
|
- |
LPG | $5,309 | 163 |
MMBtu
|
$32.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,402 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,885 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $587 | - |
$587
6,909
kWh
|
- | - | - | |
02 | 2.7135: Install occupancy sensors | $519 | $837 |
$519
3,102
kWh
|
- | - | - | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $585 | $2,079 |
$585
6,880
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,625 | - |
$1,135
13,386
kWh
|
$490
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,507 | $532 |
$3,507
30,761
kWh
|
- | - | - | |
06 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $1,117 | $981 |
$1,117
13,139
kWh
|
- | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $677 | $800 |
$677
7,966
kWh
|
- | - | - | |
08 | 2.323: | $2,066 | - | - |
$2,066
-
kW-mo/yr
|
- | - | |
09 | 2.8123: Pay utility bills on time | $477 | - | - | - | - | $477 | |
10 | 2.4133: Use most efficient type of electric motors | $2,802 | - |
$1,509
17,749
kWh
|
$1,293
-
kW-mo/yr
|
- | - | |
11 | 3.8143: Recycle cleaning solvent and reuse | $3,440 | $20,000 | - | - |
$3,440
-
gal
|
- | |
TOTAL RECOMMENDED | $17,402 | $25,229 |
$9,636
99,892
kWh
|
$3,849
-
kW-mo/yr
|
$3,440
-
gal
|
$477 | ||
TOTAL IMPLEMENTED | $3,885 | $1,637 |
$2,918
31,363
kWh
|
$490
-
kW-mo/yr
|
- | $477 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs