| Assessment Year | 2009 |
|---|---|
| Principal Product | Spunbonded Nylon Nonwoven Fabric |
| NAICS | 313230: Nonwoven Fabric Mills |
| SIC | 2297: Non-woven Fabrics |
| Sales Range | $100 M to 500M |
| # of Employees | 300 |
| Plant Area |
120,000
ft2
|
| Annual Production | 150,000
thousand feet
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,616,248 | 23,110,537 |
kWh
|
$0.070 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $220,722 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $41,548 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,614 | $1,161 |
$15,614
223,056
kWh
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $31,555 | $5,068 |
$31,555
450,785
kWh
|
|
| 03 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $9,291 | $261 |
$9,291
132,725
kWh
|
|
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $139,755 | $50,000 |
$139,755
1,996,493
kWh
|
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $1,761 | - |
$1,761
25,159
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,882 | $26,728 |
$14,882
212,605
kWh
|
|
| 07 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $7,864 | $6,675 |
$7,864
112,345
kWh
|
|
| TOTAL RECOMMENDED | $220,722 | $89,893 |
$220,722
3,153,168
kWh
|
||
| TOTAL IMPLEMENTED | $41,548 | $28,150 |
$41,548
593,545
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs