Assessment Year | 2009 |
---|---|
Principal Product | camshaft |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
156,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $450,790 | 5,431,200 |
kWh
|
$0.083 |
Electricity Demand | $10,629 | 1,146 |
kW-mo/yr
|
$9.28 |
Natural Gas | $27,953 | 11,435 |
MMBtu
|
$2.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $179,398 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $10,674 | - | - | - | - | $10,674 | |
02 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $5,219 | $2,785 |
$5,219
62,883
kWh
|
- | - | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $30,946 | $12,360 |
$30,946
356,580
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $38,121 | $39,435 |
$31,378
378,050
kWh
|
$6,743
-
kW-mo/yr
|
- | - | |
05 | 2.2442: Preheat combustion air with waste heat | $5,022 | $10,000 | - | - |
$5,022
-
MMBtu
|
- | |
06 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $21,915 | $607 |
$21,915
264,034
kWh
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,325 | $900 |
$4,325
40,424
kWh
|
- | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,248 | - |
$3,248
30,359
kWh
|
- | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $13,954 | $3,000 |
$13,954
168,118
kWh
|
- | - | - | |
10 | 2.6212: Turn off equipment during breaks, reduce operating time | $28,013 | - |
$28,013
337,500
kWh
|
- | - | - | |
11 | 2.4133: Use most efficient type of electric motors | $7,628 | $33,595 |
$3,827
46,108
kWh
|
$3,801
-
kW-mo/yr
|
- | - | |
12 | 2.7111: Reduce illumination to minimum necessary levels | $10,333 | $760 |
$8,505
102,461
kWh
|
$1,828
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $179,398 | $103,442 |
$151,330
1,786,517
kWh
|
$12,372
-
kW-mo/yr
|
$5,022
-
MMBtu
|
$10,674 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs