Assessment Year | 2007 |
---|---|
Principal Product | coolers |
NAICS | 326140: Polystyrene Foam Product Manufacturing |
SIC | 3086: Plastics Foam Products |
Sales Range | $1 M to 5M |
# of Employees | 29 |
Plant Area |
40,800
ft2
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $38,528 | 652,080 |
kWh
|
$0.059 |
Electricity Demand | $27,235 | 4,120 |
kW-mo/yr
|
$6.61 |
Natural Gas | $141,362 | 12,154 |
MMBtu
|
$11.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $119,168 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $92,909 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2515: Use optimum thickness insulation | $45,739 | $1,287 | - | - |
$45,739
-
MMBtu
|
- | |
02 | 2.2515: Use optimum thickness insulation | $10,863 | $369 | - | - |
$10,863
-
MMBtu
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $22,502 | $4,417 | - | - |
$22,502
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,757 | $5,610 |
$2,996
49,920
kWh
|
$761
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $603 | $230 |
$603
10,051
kWh
|
- | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $2,133 | $15,174 |
$1,181
20,187
kWh
|
$952
-
kW-mo/yr
|
- | - | |
07 | 2.1321: Replace fossil fuel equipment with electrical equipment | $5,571 | $15,174 | - | - |
$5,571
-
MMBtu
|
- | |
08 | 2.6231: Utilize controls to operate equipment only when needed | $28,000 | $270 | - | - | - | $28,000 | |
TOTAL RECOMMENDED | $119,168 | $42,531 |
$4,780
80,158
kWh
|
$1,713
-
kW-mo/yr
|
$84,675
-
MMBtu
|
$28,000 | ||
TOTAL IMPLEMENTED | $92,909 | $32,504 |
$1,784
30,238
kWh
|
$952
-
kW-mo/yr
|
$62,173
-
MMBtu
|
$28,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs