Assessment Year | 2007 |
---|---|
Principal Product | Produce |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | $10 M to 50M |
# of Employees | 94 |
Plant Area |
126,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $226,148 | 3,683,520 |
kWh
|
$0.061 |
Electricity Demand | $42,546 | 7,052 |
kW-mo/yr
|
$6.03 |
Other Gas | $1,000,000 | 45,263 |
MMBtu
|
$22.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $180,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,803 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,632 | $9,727 |
$23,224
372,590
kWh
|
$3,408
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,731 | - |
$4,731
47,158
kWh
|
- | - | |
03 | 2.7141: Lower light fixtures in high ceiling areas | $1,930 | $624 |
$1,662
26,812
kWh
|
$268
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $4,182 | $928 |
$4,182
67,448
kWh
|
- | - | |
05 | 2.6125: Keep equipment clean | $3,059 | $87 |
$3,059
29,489
kWh
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,583 | $21,927 |
$27,583
377,852
kWh
|
- | - | |
07 | 2.2531: Re-size charging openings or add movable cover or door | $653 | $511 |
$653
10,537
kWh
|
- | - | |
08 | 2.6231: Utilize controls to operate equipment only when needed | $111,825 | $230 | - | - | $111,825 | |
TOTAL RECOMMENDED | $180,595 | $34,034 |
$65,094
931,886
kWh
|
$3,676
-
kW-mo/yr
|
$111,825 | ||
TOTAL IMPLEMENTED | $35,803 | $11,366 |
$32,127
496,339
kWh
|
$3,676
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs