Assessment Year | 2006 |
---|---|
Principal Product | electronics |
NAICS | 334111: Electronic Computer Manufacturing |
SIC | 3571: Electronic Computers |
Sales Range | $10 M to 50M |
# of Employees | 76 |
Plant Area |
96,000
ft2
|
Annual Production | 1,098
ton
|
Production Hrs. Annual | 2,805
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $71,793 | 894,000 |
kWh
|
$0.080 |
Electricity Demand | $9,802 | 2,589 |
kW-mo/yr
|
$3.79 |
Natural Gas | $28,493 | 4,512 |
MMBtu
|
$6.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,640,205 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,968 | $27,399 |
$3,336
48,350
kWh
|
$632
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,222 | $2,053 |
$1,025
14,863
kWh
|
$197
-
kW-mo/yr
|
- | |
03 | 2.7131: Add area lighting switches | $878 | $2,646 |
$878
12,719
kWh
|
- | - | |
04 | 4.651: Install back-up equipment | $1,632,456 | $5,315 | - |
$456
-
kW-mo/yr
|
$1,632,000 | |
05 | 2.7229: Air condition only space necessary | $1,014 | $3,200 |
$1,014
14,696
kWh
|
- | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $150 | $1,480 |
$102
1,477
kWh
|
$48
-
kW-mo/yr
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $369 | - |
$369
966
kWh
|
- | - | |
08 | 2.7221: Lower temperature during the winter season and vice-versa | $148 | - |
$148
1,849
kWh
|
- | - | |
TOTAL RECOMMENDED | $1,640,205 | $42,093 |
$6,872
94,920
kWh
|
$1,333
-
kW-mo/yr
|
$1,632,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs