Assessment Year | 2005 |
---|---|
Principal Product | Scrap Metal |
NAICS | 331492: Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) |
SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
Sales Range | $10 M to 50M |
# of Employees | 28 |
Plant Area |
873,000
ft2
|
Annual Production | 100
ton
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,746 | 249,453 |
kWh
|
$0.12 |
Coal | $102,331 | 55,489 |
MMBtu
|
$1.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,239 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,122 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Coal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $10,279 | - |
$10,279
90,168
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $839 | - |
$839
7,357
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $627 | - |
$627
5,504
kWh
|
- | - | |
04 | 2.7134: Use photocell controls | $448 | - |
$448
3,931
kWh
|
- | - | |
05 | 4.632: Change operating conditions | $15,046 | - | - |
$46
-
MMBtu
|
$15,000 | |
TOTAL RECOMMENDED | $27,239 | - |
$12,193
106,960
kWh
|
$46
-
MMBtu
|
$15,000 | ||
TOTAL IMPLEMENTED | $16,122 | - |
$1,076
9,435
kWh
|
$46
-
MMBtu
|
$15,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs