Assessment Year | 2002 |
---|---|
Principal Product | Aggregate |
NAICS |
n/a
|
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $50 M to 100M |
# of Employees | 44 |
Plant Area |
840,000
ft2
|
Annual Production | 500,000
ton
|
Production Hrs. Annual | 7,000
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,082 | 2,816,240 |
kWh
|
$0.028 |
Electricity Demand | $150,782 | 8,268 |
kW-mo/yr
|
$18.24 |
Electricity Fees | $4,459 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,637 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $59,075 | $182,900 |
$17,291
613,600
kWh
|
$41,784
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,000 | $10,035 |
$6,000
182,713
kWh
|
- | - | |
03 | 2.7233: Use properly designed and sized hvac equipment | $4,407 | $500 |
$4,407
156,950
kWh
|
- | - | |
04 | 2.2511: Insulate bare equipment | $2,000 | $1,000 |
$1,448
44,000
kWh
|
$552
-
kW-mo/yr
|
- | |
05 | 2.4131: Size electric motors for peak operating efficiency | $1,885 | $2,786 |
$956
32,310
kWh
|
$929
-
kW-mo/yr
|
- | |
06 | 2.3212: Optimize plant power factor | $1,270 | $3,417 | - | - | $1,270 | |
TOTAL RECOMMENDED | $74,637 | $200,638 |
$30,102
1,029,573
kWh
|
$43,265
-
kW-mo/yr
|
$1,270 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs