ITAC Assessment: UF0356
ITAC logo
ITAC Assessment: UF0356
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Hand and Power Crimping Tools
NAICS 332216: Saw Blade and Handtool Manufacturing
SIC 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 71,200
ft2
Annual Production 0
pieces
Production Hrs. Annual 2,444
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $123,847 2,080,580
kWh
Electricity Demand $19,224 5,237
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,741 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,823

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.3113: Make ice during off peak hours for cooling - $150,000 - -
02 2.7447: Install vinyl strip / high speed / air curtain doors $11,843 $21,108 $11,843
236,861
kWh
-
03 2.2628: Utilize a less expensive cooling method $6,348 $2,000 $6,348
105,803
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,008 $700 $3,008
50,140
kWh
-
05 2.7141: Lower light fixtures in high ceiling areas $2,918 $1,185 $2,352
47,046
kWh
$565
-
kW-mo/yr
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,295 $2,194 $1,044
20,885
kWh
$251
-
kW-mo/yr
07 2.7135: Install occupancy sensors $1,232 $1,450 $1,232
24,632
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $96 $245 $88
1,752
kWh
$9
-
kW-mo/yr
09 3.5318: Recycle fluorescent lamps - $3,496 - -
TOTAL RECOMMENDED $26,741 $182,378 $25,915
487,119
kWh
$825
-
kW-mo/yr
TOTAL IMPLEMENTED $23,823 $31,193 $23,563
440,073
kWh
$260
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs