Assessment Year | 2003 |
---|---|
Principal Product | screen printed T shirts |
NAICS | 323113: Commercial Screen Printing |
SIC | 2396: Automotive Trimmings, Apparel Findings, and Related Products |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
70,000
ft2
|
Annual Production | 0
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $102,356 | 2,240,960 |
kWh
|
$0.046 |
Electricity Demand | $47,311 | 5,493 |
kW-mo/yr
|
$8.61 |
Natural Gas | $9,710 | 3,269 |
MMBtu
|
$2.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,009 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $51,285 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $7,390 | $2,948 |
$7,390
110,473
kWh
|
- | - | - | |
02 | 2.2511: Insulate bare equipment | $1,530 | $868 | - | - |
$1,530
-
MMBtu
|
- | |
03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $17,331 | $45,500 |
$17,331
258,669
kWh
|
- | - | - | |
04 | 2.2628: Utilize a less expensive cooling method | $7,451 | $740 |
$7,451
111,208
kWh
|
- | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,598 | $376 |
$1,446
31,451
kWh
|
$2,152
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,755 | $852 |
$2,115
45,985
kWh
|
$640
-
kW-mo/yr
|
- | - | |
07 | 2.7141: Lower light fixtures in high ceiling areas | $15,954 | $436 |
$11,656
233,626
kWh
|
$4,298
-
kW-mo/yr
|
- | - | |
08 | 4.132: Purchase new equipment to reduce material use / cost | $18,000 | $4,000 | - | - | - | $18,000 | |
TOTAL RECOMMENDED | $74,009 | $55,720 |
$47,389
791,412
kWh
|
$7,090
-
kW-mo/yr
|
$1,530
-
MMBtu
|
$18,000 | ||
TOTAL IMPLEMENTED | $51,285 | $49,936 |
$28,987
492,295
kWh
|
$4,298
-
kW-mo/yr
|
- | $18,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs