Assessment Year | 2002 |
---|---|
Principal Product | Orange Juice, Orange Juice Concentrate |
NAICS |
n/a
|
SIC | 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
31,000
ft2
|
Annual Production | 4,000,000
pieces
|
Production Hrs. Annual | 4,896
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $336,884 | 7,683,794 |
kWh
|
$0.044 |
Electricity Demand | $30,022 | 18,967 |
kW-mo/yr
|
$1.58 |
Natural Gas | $545,991 | 134,774 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $240,286 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,016 | - |
$1,016
23,242
kWh
|
- | - | - | - | - | |
02 | 2.7132: Install timers on light switches in little used areas | $1,352 | $134 |
$1,352
28,156
kWh
|
- | - | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $809 | - |
$809
16,857
kWh
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,526 | $1,768 |
$2,322
52,779
kWh
|
$204
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.2424: Use heat in flue gases to preheat products or materials | $51,092 | $121,957 | - | - |
$51,092
-
MMBtu
|
- | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $16,517 | $16,521 |
$15,178
344,963
kWh
|
$1,339
-
kW-mo/yr
|
- | - | - | - | |
07 | 3.5311: Recover and reuse waste material | $40,494 | $1,035 | - | - | - |
$40,494
-
gal
|
- | - | |
08 | 4.231: Purchase equipment instead of leasing | $70,176 | - | - | - | - | - | $70,176 | - | |
09 | 4.425: Eliminate/reduce redundant inspections | $56,304 | $376 | - | - | - | - | - | $56,304 | |
TOTAL RECOMMENDED | $240,286 | $141,791 |
$20,677
465,997
kWh
|
$1,543
-
kW-mo/yr
|
$51,092
-
MMBtu
|
$40,494
-
gal
|
$70,176 | $56,304 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs