Assessment Year | 2002 |
---|---|
Principal Product | Labels |
NAICS |
n/a
|
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
76,000
ft2
|
Annual Production | 28,500,000
lb
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,772 | 2,656,097 |
kWh
|
$0.040 |
Electricity Demand | $32,542 | 6,992 |
kW-mo/yr
|
$4.65 |
Natural Gas | $183,031 | 21,521 |
MMBtu
|
$8.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,846 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $2,667 | $654 |
$2,667
48,315
kWh
|
- | - | - | - | - | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,905 | $4,220 | - | - | - |
$5,905
-
MMBtu
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $5,603 | $14,749 |
$4,375
108,839
kWh
|
$1,228
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $651 | - |
$651
11,798
kWh
|
- | - | - | - | - | |
05 | 2.2511: Insulate bare equipment | $3,038 | $820 | - | - |
$3,038
-
MMBtu
|
- | - | - | |
06 | 2.7134: Use photocell controls | $4,538 | $20,450 |
$2,841
70,720
kWh
|
$1,897
-
kW-mo/yr
|
- | - | $(-200.0) | - | |
07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $10,139 | $18,574 |
$10,139
183,694
kWh
|
- | - | - | - | - | |
08 | 2.2511: Insulate bare equipment | $8,307 | $2,282 | - | - |
$8,307
-
MMBtu
|
- | - | - | |
09 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $11,700 | $7,000 | - | - | - | - | $11,700 | - | |
10 | 4.112: Replace old machine with new automatic multi-station tool | $8,320 | $32,000 | - | - | - | - | $8,320 | - | |
11 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,880 | $13,500 | - | - | - | - | - | $2,880 | |
TOTAL RECOMMENDED | $63,748 | $114,249 |
$20,673
423,366
kWh
|
$3,125
-
kW-mo/yr
|
$11,345
-
MMBtu
|
$5,905
-
MMBtu
|
$19,820 | $2,880 | ||
TOTAL IMPLEMENTED | $34,846 | $58,623 |
$7,693
168,952
kWh
|
$1,228
-
kW-mo/yr
|
- |
$5,905
-
MMBtu
|
$20,020 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs