| Assessment Year | 2001 |
|---|---|
| Principal Product | Corn and Flour Tortillas |
| NAICS |
n/a
|
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 55 |
| Plant Area |
18,000
ft2
|
| Annual Production | 10,500,000
lb
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,532 | 772,779 |
kWh
|
$0.052 |
| Electricity Demand | $18,385 | 2,138 |
kW-mo/yr
|
$8.60 |
| Natural Gas | $73,520 | 11,470 |
MMBtu
|
$6.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,812 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $27,445 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4151: Develop a repair/replace policy | $1,737 | $624 |
$1,314
25,266
kWh
|
$423
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,067 | $1,072 |
$577
11,092
kWh
|
$490
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.7145: Install skylights | $2,866 | $3,569 |
$1,679
32,291
kWh
|
$1,187
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 2.2136: Install / repair insulation on steam lines | $669 | $101 |
$669
12,867
kWh
|
- | - | - | - | - | - | |
| 05 | 2.2221: Use immersion heating in tanks, melting pots, etc | $7,697 | $25,000 |
$8,412
161,763
kWh
|
$3,210
-
kW-mo/yr
|
$(-3,925.0)
-
MMBtu
|
- | - | - | - | |
| 06 | 3.4155: Meter waste water | $778 | $1,500 | - | - | - |
$778
-
Tgal
|
- | - | - | |
| 07 | 4.821: Pay bills on time to avoid late fees | $288 | - | - | - | - | - | - | $288 | - | |
| 08 | 4.114: Add/modify equipment to improve drying process | $4,760 | $2,000 | - | - | - | - | - | - | $4,760 | |
| 09 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $20,950 | $11,700 |
$958
12,600
kWh
|
- | - | - | $19,992 | - | - | |
| TOTAL RECOMMENDED | $40,812 | $45,566 |
$13,609
255,879
kWh
|
$5,310
-
kW-mo/yr
|
$(-3,925.0)
-
MMBtu
|
$778
-
Tgal
|
$19,992 | $288 | $4,760 | ||
| TOTAL IMPLEMENTED | $27,445 | $15,301 |
$1,627
25,467
kWh
|
- | - |
$778
-
Tgal
|
$19,992 | $288 | $4,760 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs