Assessment Year 2000
Principal Product Steel Bridges
NAICS
n/a
SIC 3441: Fabricated Structural Metal
Sales Range $10
M
to 50
M
# of Employees 115
Plant Area 102,000
ft2
Annual Production 20,000
ton
Production Hrs. Annual 3,744
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $55,899 1,584,994
kWh
Electricity Demand $33,067 5,769
kW-mo/yr
Electricity Fees $2,439 -
LPG $2,312 117
MMBtu
Fuel Oil #2 $21,858 3,427
MMBtu
Other Gas $19,212 3,225
MMBtu
Other Energy $33,632 97
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $457,867 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $430,638

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $602 $1,780 $464
12,309
kWh
$138
-
kW-mo/yr
- - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,723 $4,896 $5,646
148,593
kWh
$2,077
-
kW-mo/yr
- - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,112 $220 $2,112
36,928
kWh
- - - - -
04 2.4231: Reduce the pressure of compressed air to the minimum required $754 - $754
13,189
kWh
- - - - -
05 4.651: Install back-up equipment $19,506 $68,780 - - $(-247.0)
-
MMBtu
- $(-2,000.0) $21,753
06 3.5248: Separate and recycle scrap metal to foundry or for sale $160,010 - - - - $160,010
-
lb
- -
07 4.446: Automate finishing process $159,000 $76,000 - - - - - $159,000
08 4.446: Automate finishing process $108,160 $150,150 - - - - $108,160 -
TOTAL RECOMMENDED $457,867 $301,826 $8,976
211,019
kWh
$2,215
-
kW-mo/yr
$(-247.0)
-
MMBtu
$160,010
-
lb
$106,160 $180,753
TOTAL IMPLEMENTED $430,638 $228,150 $3,330
62,426
kWh
$138
-
kW-mo/yr
- $160,010
-
lb
$108,160 $159,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings