Assessment Year | 2000 |
---|---|
Principal Product | Steel Bridges |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
102,000
ft2
|
Annual Production | 20,000
ton
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,899 | 1,584,994 |
kWh
|
$0.035 |
Electricity Demand | $33,067 | 5,769 |
kW-mo/yr
|
$5.73 |
Electricity Fees | $2,439 | - |
|
- |
LPG | $2,312 | 117 |
MMBtu
|
$19.76 |
Fuel Oil #2 | $21,858 | 3,427 |
MMBtu
|
$6.38 |
Other Gas | $19,212 | 3,225 |
MMBtu
|
$5.96 |
Other Energy | $33,632 | 97 |
MMBtu
|
$346.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $457,867 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $430,638 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $602 | $1,780 |
$464
12,309
kWh
|
$138
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,723 | $4,896 |
$5,646
148,593
kWh
|
$2,077
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,112 | $220 |
$2,112
36,928
kWh
|
- | - | - | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $754 | - |
$754
13,189
kWh
|
- | - | - | - | - | |
05 | 4.651: Install back-up equipment | $19,506 | $68,780 | - | - |
$(-247.0)
-
MMBtu
|
- | $(-2,000.0) | $21,753 | |
06 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $160,010 | - | - | - | - |
$160,010
-
lb
|
- | - | |
07 | 4.446: Automate finishing process | $159,000 | $76,000 | - | - | - | - | - | $159,000 | |
08 | 4.446: Automate finishing process | $108,160 | $150,150 | - | - | - | - | $108,160 | - | |
TOTAL RECOMMENDED | $457,867 | $301,826 |
$8,976
211,019
kWh
|
$2,215
-
kW-mo/yr
|
$(-247.0)
-
MMBtu
|
$160,010
-
lb
|
$106,160 | $180,753 | ||
TOTAL IMPLEMENTED | $430,638 | $228,150 |
$3,330
62,426
kWh
|
$138
-
kW-mo/yr
|
- |
$160,010
-
lb
|
$108,160 | $159,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs