Assessment Year | 1999 |
---|---|
Principal Product | Plastic Bottles |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $50 M to 100M |
# of Employees | 60 |
Plant Area |
193,000
ft2
|
Annual Production | 700,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $504,065 | 13,771,981 |
kWh
|
$0.037 |
Electricity Demand | $220,830 | 28,277 |
kW-mo/yr
|
$7.81 |
Electricity Fees | $105,348 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $514,247 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $59,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $192,386 | $82,242 |
$313,544
7,126,905
kWh
|
$74,570
-
kW-mo/yr
|
$(-195,728.0)
-
MMBtu
|
- | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $8,006 | $60 |
$6,427
145,955
kWh
|
$1,579
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $5,521 | $1,500 |
$5,521
125,440
kWh
|
- | - | - | - | - | |
04 | 2.7135: Install occupancy sensors | $1,539 | $834 |
$1,539
34,877
kWh
|
- | - | - | - | - | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,215 | - |
$1,078
24,619
kWh
|
$2,137
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.1163: Use plastic pallets instead of wood | $25,200 | $14,070 | - | - | - |
$25,200
-
lb
|
- | - | |
07 | 4.441: Install automatic packing equipment | $262,532 | $850,000 | - | - | - | - | $262,532 | - | |
08 | 4.125: | $15,848 | $75,000 | - | - | - | - | - | $15,848 | |
TOTAL RECOMMENDED | $514,247 | $1,023,706 |
$328,109
7,457,796
kWh
|
$78,286
-
kW-mo/yr
|
$(-195,728.0)
-
MMBtu
|
$25,200
-
lb
|
$262,532 | $15,848 | ||
TOTAL IMPLEMENTED | $59,329 | $91,464 |
$14,565
330,891
kWh
|
$3,716
-
kW-mo/yr
|
- |
$25,200
-
lb
|
- | $15,848 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs