Assessment Year 1998
Principal Product Newspaper Printing and Publishing
NAICS
n/a
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $50
M
to 100
M
# of Employees 430
Plant Area 180,000
ft2
Annual Production 3,500,000
pieces
Production Hrs. Annual 6,753
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $410,902 8,985,639
kWh
Electricity Demand $205,598 23,040
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $63,028 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,106

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $13,048 $40,581 $9,150
199,004
kWh
$3,898
-
kW-mo/yr
-
02 2.7135: Install occupancy sensors $6,122 $9,656 $6,122
133,060
kWh
- -
03 2.4133: Use most efficient type of electric motors $551 $5,948 $345
7,620
kWh
$206
-
kW-mo/yr
-
04 2.4226: Use / purchase optimum sized compressor $7,361 $3,316 $4,085
88,804
kWh
$3,276
-
kW-mo/yr
-
05 2.2437: Recover waste heat from equipment $10,820 $4,000 $6,077
132,181
kWh
$4,743
-
kW-mo/yr
-
06 3.5248: Separate and recycle scrap metal to foundry or for sale $3,450 - - - $3,450
07 3.5311: Recover and reuse waste material $570 - - - $570
08 4.812: Apply for investment incentives $21,106 - - - $21,106
TOTAL RECOMMENDED $63,028 $63,501 $25,779
560,669
kWh
$12,123
-
kW-mo/yr
$25,126
TOTAL IMPLEMENTED $21,106 - - - $21,106
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs