| Assessment Year | 1998 |
|---|---|
| Principal Product | Newspaper Printing and Publishing |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $50 M to 100M |
| # of Employees | 430 |
| Plant Area |
180,000
ft2
|
| Annual Production | 3,500,000
pieces
|
| Production Hrs. Annual | 6,753
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $410,902 | 8,985,639 |
kWh
|
$0.046 |
| Electricity Demand | $205,598 | 23,040 |
kW-mo/yr
|
$8.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $63,028 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,106 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,048 | $40,581 |
$9,150
199,004
kWh
|
$3,898
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $6,122 | $9,656 |
$6,122
133,060
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $551 | $5,948 |
$345
7,620
kWh
|
$206
-
kW-mo/yr
|
- | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $7,361 | $3,316 |
$4,085
88,804
kWh
|
$3,276
-
kW-mo/yr
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $10,820 | $4,000 |
$6,077
132,181
kWh
|
$4,743
-
kW-mo/yr
|
- | |
| 06 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $3,450 | - | - | - | $3,450 | |
| 07 | 3.5311: Recover and reuse waste material | $570 | - | - | - | $570 | |
| 08 | 4.812: Apply for investment incentives | $21,106 | - | - | - | $21,106 | |
| TOTAL RECOMMENDED | $63,028 | $63,501 |
$25,779
560,669
kWh
|
$12,123
-
kW-mo/yr
|
$25,126 | ||
| TOTAL IMPLEMENTED | $21,106 | - | - | - | $21,106 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs