Assessment Year | 1998 |
---|---|
Principal Product | Fried and frozen eggplant |
NAICS |
n/a
|
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 30 |
Plant Area |
8,000
ft2
|
Annual Production | 4,500,000
lb
|
Production Hrs. Annual | 1,768
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,196 | 730,950 |
kWh
|
$0.054 |
Electricity Demand | $36,738 | 4,370 |
kW-mo/yr
|
$8.41 |
LPG | $4,771 | 333 |
MMBtu
|
$14.33 |
Other Energy | $340,035 | 1,618 |
MMBtu
|
$210.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $271,156 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,877 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,855 | - |
$1,431
26,377
kWh
|
$424
-
kW-mo/yr
|
- | - | - | |
02 | 2.7135: Install occupancy sensors | $2,494 | $575 |
$2,494
46,307
kWh
|
- | - | - | - | |
03 | 2.6218: Turn off equipment when not in use | $2,611 | - |
$2,611
62,720
kWh
|
- | - | - | - | |
04 | 2.4322: Use or replace with energy efficient substitutes | $116,629 | $161,349 | - | - | - |
$116,629
-
MMBtu
|
- | |
05 | 2.4311: Recover mechanical energy | $4,771 | $18,000 | - | - |
$4,771
-
MMBtu
|
- | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $674 | $530 |
$674
14,361
kWh
|
- | - | - | - | |
07 | 2.8114: Change rate schedules or other changes in utility service | $8,185 | $890 | - | - | - | - | $8,185 | |
08 | 3.1182: Make a new by-product | $102,530 | $115,500 | - | - | - | - | $102,530 | |
09 | 2.8121: Apply for tax-free status for energy purchases | $4,887 | $50 | - | - | - | - | $4,887 | |
10 | 4.112: Replace old machine with new automatic multi-station tool | $26,520 | $60,000 | - | - | - | - | $26,520 | |
TOTAL RECOMMENDED | $271,156 | $356,894 |
$7,210
149,765
kWh
|
$424
-
kW-mo/yr
|
$4,771
-
MMBtu
|
$116,629
-
MMBtu
|
$142,122 | ||
TOTAL IMPLEMENTED | $42,877 | $61,470 |
$3,285
77,081
kWh
|
- | - | - | $39,592 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Energy Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs