Assessment Year | 1998 |
---|---|
Principal Product | Polyester Monofilament Fabrics |
NAICS |
n/a
|
SIC | 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk |
Sales Range | $10 M to 50M |
# of Employees | 104 |
Plant Area |
182,000
ft2
|
Annual Production | 1,884
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $370,852 | 6,388,042 |
kWh
|
$0.058 |
Electricity Demand | $56,919 | 13,311 |
kW-mo/yr
|
$4.28 |
Natural Gas | $20,719 | 2,488 |
MMBtu
|
$8.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,034 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $54,003 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,329 | $6,792 |
$2,951
50,996
kWh
|
$378
-
kW-mo/yr
|
- | - | |
02 | 2.7135: Install occupancy sensors | $6,021 | $3,354 |
$6,021
103,751
kWh
|
- | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $1,770 | - |
$1,770
30,481
kWh
|
- | - | - | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $2,597 | $3,755 |
$1,871
32,239
kWh
|
$726
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,451 | $2,600 |
$13,371
199,590
kWh
|
- | - | $(-1,920.0) | |
06 | 2.4226: Use / purchase optimum sized compressor | $3,511 | $15,000 |
$2,629
45,428
kWh
|
$882
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,269 | - |
$3,269
48,652
kWh
|
- | - | - | |
08 | 2.2437: Recover waste heat from equipment | $1,732 | $2,050 | - | - |
$1,732
-
MMBtu
|
- | |
09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,125 | - | - | - | - | $1,125 | |
10 | 4.821: Pay bills on time to avoid late fees | $2,071 | - | - | - | - | $2,071 | |
11 | 2.8121: Apply for tax-free status for energy purchases | $24,315 | $50 | - | - | - | $24,315 | |
12 | 4.521: Clear and rent existing space | $13,843 | - | - | - | - | $13,843 | |
TOTAL RECOMMENDED | $75,034 | $33,601 |
$31,882
511,137
kWh
|
$1,986
-
kW-mo/yr
|
$1,732
-
MMBtu
|
$39,434 | ||
TOTAL IMPLEMENTED | $54,003 | $2,650 |
$16,640
248,242
kWh
|
- | - | $37,363 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs