Assessment Year | 1998 |
---|---|
Principal Product | Precious metal processing |
NAICS |
n/a
|
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 32 |
Plant Area |
25,000
ft2
|
Annual Production | 81,250
lb
|
Production Hrs. Annual | 2,750
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,385 | 614,009 |
kWh
|
$0.053 |
Electricity Demand | $31,624 | 3,288 |
kW-mo/yr
|
$9.62 |
Natural Gas | $46,447 | 6,175 |
MMBtu
|
$7.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,152 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,951 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,128 | $474 |
$1,128
21,688
kWh
|
- | - | |
02 | 2.7134: Use photocell controls | $466 | $1,260 |
$466
9,086
kWh
|
- | - | |
03 | 2.4224: Upgrade controls on compressors | $750 | $60 |
$82
1,465
kWh
|
$334
-
kW-mo/yr
|
$334 | |
04 | 2.4133: Use most efficient type of electric motors | $249 | $1,716 |
$144
2,638
kWh
|
$105
-
kW-mo/yr
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $614 | $53 |
$345
6,741
kWh
|
$269
-
kW-mo/yr
|
- | |
06 | 3.1192: Reduce scrap production | $186 | $1,400 |
$108
2,052
kWh
|
$31
-
kW-mo/yr
|
$47 | |
07 | 2.3191: Use demand controller or load shedder | $7,846 | $811 | - |
$7,846
-
kW-mo/yr
|
- | |
08 | 2.7314: Reduce ventilation air | $2,283 | $2,700 |
$1,280
24,619
kWh
|
$1,003
-
kW-mo/yr
|
- | |
09 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $720 | - | - | - | $720 | |
10 | 3.1192: Reduce scrap production | $587 | - | - | - | $587 | |
11 | 2.8121: Apply for tax-free status for energy purchases | $2,027 | $750 | - | - | $2,027 | |
12 | 4.652: Replace existing equipment with more suitable substitutes | $10,296 | $1,677 | - | - | $10,296 | |
13 | 3.2176: Increase use of automation | $20,000 | $10 | - | - | $20,000 | |
TOTAL RECOMMENDED | $47,152 | $10,911 |
$3,553
68,289
kWh
|
$9,588
-
kW-mo/yr
|
$34,011 | ||
TOTAL IMPLEMENTED | $45,951 | $10,858 |
$3,208
61,548
kWh
|
$9,319
-
kW-mo/yr
|
$33,424 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |