Assessment Year | 1997 |
---|---|
Principal Product | Manufactured Homes |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 237 |
Plant Area |
130,000
ft2
|
Annual Production | 2,750
pieces
|
Production Hrs. Annual | 2,700
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,469 | 864,302 |
kWh
|
$0.049 |
Electricity Demand | $32,374 | 3,475 |
kW-mo/yr
|
$9.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $211,553 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,578 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $346 | $3,549 |
$187
3,810
kWh
|
$159
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,088 | $1,850 |
$2,088
42,497
kWh
|
- | - | - | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $1,663 | - | - |
$1,663
-
kW-mo/yr
|
- | - | - | |
04 | 3.1192: Reduce scrap production | $167,231 | $165,000 |
$(-1,911.0)
(-38,980)
kWh
|
$(-2,790.0)
-
kW-mo/yr
|
$(-1,142.0)
-
lb
|
- | $173,074 | |
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $622 | $850 | - | - | - | $622 | - | |
06 | 3.5311: Recover and reuse waste material | $29,205 | - | - | - |
$41,805
-
lb
|
$(-12,600.0) | - | |
07 | 3.1175: Use a different or recycled raw material | $7,964 | - | - | - | - | - | $7,964 | |
08 | 2.8121: Apply for tax-free status for energy purchases | $2,434 | - | - | - | - | $2,434 | - | |
TOTAL RECOMMENDED | $211,553 | $171,249 |
$364
7,327
kWh
|
$(-968.0)
-
kW-mo/yr
|
$40,663
-
lb
|
$(-9,544.0) | $181,038 | ||
TOTAL IMPLEMENTED | $33,578 | $2,700 |
$2,088
42,497
kWh
|
$1,663
-
kW-mo/yr
|
$41,805
-
lb
|
$(-11,978.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs