ITAC Assessment: UF0175
ITAC logo
ITAC Assessment: UF0175
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Manufactured Homes
NAICS
n/a
SIC 2451: Mobile Homes
Sales Range $10
M
to 50
M
# of Employees 237
Plant Area 130,000
ft2
Annual Production 2,750
pieces
Production Hrs. Annual 2,700
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,469 864,302
kWh
Electricity Demand $32,374 3,475
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $211,553 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $33,578

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings Primary Raw Material Savings
01 2.4133: Use most efficient type of electric motors $346 $3,549 $187
3,810
kWh
$159
-
kW-mo/yr
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,088 $1,850 $2,088
42,497
kWh
- - - -
03 2.4226: Use / purchase optimum sized compressor $1,663 - - $1,663
-
kW-mo/yr
- - -
04 3.1192: Reduce scrap production $167,231 $165,000 $(-1,911.0)
(-38,980)
kWh
$(-2,790.0)
-
kW-mo/yr
$(-1,142.0)
-
lb
- $173,074
05 3.4116: Meter recycled water (to reduce sewer charges) $622 $850 - - - $622 -
06 3.5311: Recover and reuse waste material $29,205 - - - $41,805
-
lb
$(-12,600.0) -
07 3.1175: Use a different or recycled raw material $7,964 - - - - - $7,964
08 2.8121: Apply for tax-free status for energy purchases $2,434 - - - - $2,434 -
TOTAL RECOMMENDED $211,553 $171,249 $364
7,327
kWh
$(-968.0)
-
kW-mo/yr
$40,663
-
lb
$(-9,544.0) $181,038
TOTAL IMPLEMENTED $33,578 $2,700 $2,088
42,497
kWh
$1,663
-
kW-mo/yr
$41,805
-
lb
$(-11,978.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs