ITAC Assessment: UF0155
ITAC logo
ITAC Assessment: UF0155
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Metal Clad Building Panels
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 115
Plant Area 235,000
ft2
Annual Production 12,000
thousand feet
Production Hrs. Annual 3,120
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $106,486 1,939,332
kWh
Electricity Demand $26,941 5,736
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $63,052 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $63,052

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.7132: Install timers on light switches in little used areas $4,760 $860 $4,760
86,460
kWh
- -
02 2.4133: Use most efficient type of electric motors $2,464 $853 $1,853
33,705
kWh
$611
-
kW-mo/yr
-
03 2.4239: Eliminate or reduce compressed air usage $6,362 $1,600 $6,362
92,321
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,264 $1,300 $5,264
76,202
kWh
- -
05 2.4226: Use / purchase optimum sized compressor $10,500 $10,500 $10,500
188,746
kWh
- -
06 2.7232: Replace existing hvac unit with high efficiency model $902 $120 $596
10,844
kWh
$306
-
kW-mo/yr
-
07 3.5316: Contract a wood pallet recycling company $32,800 - - - $32,800
-
lb
TOTAL RECOMMENDED $63,052 $15,233 $29,335
488,278
kWh
$917
-
kW-mo/yr
$32,800
-
lb
TOTAL IMPLEMENTED $63,052 $15,233 $29,335
488,278
kWh
$917
-
kW-mo/yr
$32,800
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs