Assessment Year | 1995 |
---|---|
Principal Product | Supermarket Equipment |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
250,000
ft2
|
Annual Production | 6,000
pieces
|
Production Hrs. Annual | 3,276
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $444,968 | 4,050,410 |
kWh
|
$0.11 |
Natural Gas | $16,589 | 2,151 |
MMBtu
|
$7.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,937 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,542 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,595 | $54,918 |
$25,595
213,365
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $730 | $4,270 |
$730
6,448
kWh
|
- | |
03 | 2.7271: Replace electric reheat with heat pipes | $2,103 | $3,500 |
$2,103
22,274
kWh
|
- | |
04 | 2.7132: Install timers on light switches in little used areas | $1,769 | $520 |
$1,769
18,757
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,217 | $850 |
$6,217
56,565
kWh
|
- | |
06 | 2.4225: Install common header on compressors | $3,282 | $2,500 |
$3,282
34,877
kWh
|
- | |
07 | 2.2437: Recover waste heat from equipment | $2,241 | $5,000 | - |
$2,241
-
MMBtu
|
|
TOTAL RECOMMENDED | $41,937 | $71,558 |
$39,696
352,286
kWh
|
$2,241
-
MMBtu
|
||
TOTAL IMPLEMENTED | $32,542 | $60,038 |
$32,542
276,378
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs